Skip to main content
. 2024 Jul 2;14:15209. doi: 10.1038/s41598-024-66007-y

Table 3.

Performance comparison of various LFC controllers.

Type of LFC controller Negative peak overshoot Frequency variations Settling time
pu Hz Pu Hz Sec
No controller 0.0307 1.535 0.0235 1.175 4.65
Proposed controller 0.0379 1.895 0 0 1.98
FFA controller26 0.0380 1.90 0 0 4.50
ZN controller 0.05665 2.842 0 0 1.51