Skip to main content
. 2024 Jul 9;14:15852. doi: 10.1038/s41598-024-65920-6

Table 2.

Representative parameter values. Parameters used to estimate the contributions to the pressure difference on a two-phase simulation representative of our study.

Parameter Symbol Value
Temperature (K) T 373
Absolute pressure (Pa) P 1 ×106
Pressure gradient (Pa/m) ΔP 1 ×106
Water viscosity (Pa.s) η2 28 ×10−5
Supercritical C02 viscosity (Pa.s) η1 2.22 ×10−5
Water density (Kg/m3) ρ2 960
Supercritical C02 density (Kg/m3) ρ1 145
Interfacial tension (N/m) σ 40 ×10−3
Gravitational acceleration (m/s2) g 9.81
Parameter Symbol Value
Average capillary diameter (m) D 20 ×10−6
Average capillary length (m) L 2.25 ×10−6
sinβ sinβ 0.5
Interface position approx (m) x = L/2 1.125 ×10−6
Interface speed approx (m/s) x˙ 5 ×10−3
Interface acceleration approx (m/s2) x¨ 5 ×10−3
graphic file with name 41598_2024_65920_Figa_HTML.gif