Table 2. The ablation study of MRI modalities and post-processing of masks on the BraTS-Reg 2022.

Method Modality TRE (mm)↓ Robustness↑ %|Jϕ(p)|0
DIRAC T1ce 1.91±1.06 0.82±0.24 0.14±0.20
DIRAC-D T1ce-T2 1.88±1.01 0.82±0.23 0.09±0.16
DIRAC-TT T1ce-T2 1.87±0.98 0.82±0.23 0.13±0.18
DIRAC-TF T1ce-FLAIR 1.85±0.95 0.80±0.24 0.14±0.12
DIRAC-TT-DI T1ce-T2 1.86±1.01 0.83±0.23 0.15±0.14
DIRAC-TT-CO T1ce-T2 1.84±0.99 0.84±0.19 0.15±0.16
DIRAC-TT-OD T1ce-T2 1.84±0.98 0.85±0.22 0.13±0.15
DIRAC-TF-DI T1ce-FLAIR 1.86±1.13 0.85±0.22 0.11±0.18
DIRAC-TF-CO T1ce-FLAIR 1.85±1.08 0.82±0.23 0.13±0.20
DIRAC-TF-OD T1ce-FLAIR 1.82±0.94 0.85±0.18 0.19±0.24

Results are provided as mean ± standard deviation. The D suffix indicates the introduction of the T2 modality through single-sided fusion input, the TT suffix indicates bimodal inputs with T1ce and T2, and the TF suffix indicates bimodal inputs with T1ce and FLAIR. DI, CO, and OD represent 3 post-processing methods for masks. ↑, higher is better; ↓, lower is better. MRI, magnetic resonance imaging; TRE, target registration error; T1ce, contrast-enhanced T1-weighted; FLAIR, fluid-attenuated inversion recovery.