Temperature increase of the peltier elements depending on the supplied current.

time in s 0 30 60 90 120 150 180 210 240 270 300
current in
0,5 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C
1,0 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C
1,5 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C
2,0 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 66 °C
2,5 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 66 °C 66 °C
3,0 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 66 °C 68 °C 68 °C
3,5 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 66 °C 68 °C 70 °C 70 °C
4,0 A 0 °C 0 °C 0 °C 0 °C 0 °C 0 °C 66 °C 68 °C 70 °C 75 °C 75 °C
4,5 A 0 °C 0 °C 0 °C 0 °C 0 °C 66 °C 70 °C 75 °C 80 °C 85 °C 85 °C
5,0 A 0 °C 0 °C 0 °C 0 °C 66 °C 75 °C 83 °C 90 °C 95 °C 100 °C 100 °C