Skip to main content
. 2024 Aug;40(7):1332–1337. doi: 10.12669/pjms.40.7.8779

Table-III.

Comparison of post-restorative sensitivity between titania-nanoparticle reinforced bonding agent and bonding agent without nanoparticles at three evaluation periods.

Evaluation periods Groups n Mean ranks Sum of ranks Mann- Whitney U p-value
After 24 hours A 30 24.33 730.00 265.000 0.004
B 30 36.67 1100.00
At 1 week A 30 24.20 726.00 261.000 0.002
B 30 36.80 1104.00
At 1 month A 30 30.00 900.00 435.000 0.643
B 30 31.00 930.00

*p-value 0.05. Mann- Whitney U test.