Table 1.

Description of the experimental groups with applied laser parameters and final irrigation procedure.

Group Device Parameter Irrigation procedure
Control Endodontic needle
(ENDO 30G, Transcodent, Kiel, Germany)
Inserted up to working length minus 1 mm 2 mL NaOCl after each filing step, 1 × 30 s laser activation EDTA (3 mL),
1 × 30 s laser activation distilled water (2 mL),
3 × 30 s laser activation NaOCl (3 mL),
1 × 30 s laser activation distilled water (2 mL)
1 ER:YAG laser
(LiteTouch, Light Instruments, Israel;
Tip (AS7075(×), 0.4 × 17 mm)
Ø 0.3 W
(20 mJ, 15 Hz)
Inserted in pulpal chamber
2 9.3 µm CO2 laser
(Solea, Convergent Dental, USA)
(Ultra-guide handpiece with endo-tip Ø 1.25 mm)
Ø 0.4 W
(40%, 14 Hz)
Inserted in pulpal chamber
3 WISER 808 nm
(Wiser Doctor Smile 808 nm (Lambda SpA, Brendola, Italy)
black coated tip Ø 0.2 mm;
Ø 0.4 W
(1 W, 26,666 µs on, 40,000 off)
Inserted up to working length minus 2 mm