Table 4:
Frequency mean lineal energy and dose mean lineal energy values. BPA and BSH averaged lineal energy include data for the charge exchange (this work), charge scaled (Han et al., 2023) and experimental results of Sato (Sato et al., 2018). Uncertainties are one standard deviation.
Cytoplasm | Membrane | Intercellular | ||||
---|---|---|---|---|---|---|
(keV/μm) | (keV/μm) | (keV/μm) | (keV/μm) | (keV/μm) | (keV/μm) | |
Alpha (This work) | 159.19 ± 4.24 | 211.16 ± 6.83 | 140.14 ± 4.32 | 195.02 ±7.22 | 105.42 ± 4.07 | 158.67 ± 7.49 |
Alpha (Han et.al.) | 169.67 ± 7.76 | 223.28 ± 11.85 | 149.15 ± 8.29 | 205.62 ± 14.28 | 108.55 ± 5.31 | 159.96 ± 9.51 |
Lithium (This work) | 114.12 ± 3.51 | 158.92 ± 5.88 | 21.91 ± 0.94 | 31.47 ± 1.6 | 12.61 ± 0.97 | 21.99 ± 2.47 |
Lithium (Han et. al.) | 100.24 ± 5.84 | 155.20 ± 11.44 | 9.31 ± 0.27 | 13.92 ± 0.62 | 5.79 ± 1.61 | 10.97 ± 3.69 |
Mixed | 141.12 ± 2.77 | 195.09 ± 4.77 | 101.35 ± 2.66 | 182.58 ± 6.16 | 92.24 ± 3.35 | 156.59 ± 6.97 |
BPA | BSH | |||||
Charge Exchange | Charge Scaled (Han et. al.) | Sato | Charge Exchange | Charge Scaled (Han et. al.) | Sato | |
(keV/μm) | 130.30 ± 2.25 | 137.24 | 118.43 | 96.67 ± 2.18 | 106.87 | 120.32 |
(keV/μm) | 189.05 ± 3.26 | 199.64 | 213.55 | 215.20 ± 4.51 | 182.73 | 198.21 |