Skip to main content
. 2024 Jul 29;46(9):337. doi: 10.1007/s10653-024-02132-x

Table 2.

Authors’ recommendations for values of correction factors k1m and k3m in underground facilities relative to optimal periods for conducting environmental measurements

Type of object Recommended exposure period Recommended correction factors Match compliance [%]
Cave III k1mb: 1.30 or k1mc:1.16 98% or 99% respectively
IV k1mc: 0.88 95%
V k1mc: 0.74 98%
IX k1mc: 0.95 99%
XI k1mb: 1.30, k1mc: 1.30, k1ma:1.20 98%, 98%, 90% respectively
XII k1mb: 1.50 or k1mc:1.60 95% or 97% respectively
Tourist route in mine III k1ma:1.56 90%
IV k1mc: 0.96 or k1mb: 0.88 98% or 90% respectively
IX k1ma: 0.63 95%
Mining company

In colder period:

XII

k1mc or k1md

1.60

For mining area (range):

58–98%

Tourist route in abandoned uranium mine Quarter no. 1 (January-March) k3ma: 0.62 82%
Quarter no. 2 (April-June) k3ma: 0.76 82%
Quarter no. 3 (July–September) k3ma: 2.14 88%
Quarter no. 4 (October-December) k3mb: 1.31 80%
Inhalatorium in abandoned uranium mine Quarter no. 1 (January-March) k3mb:1.40, k3ma: 0.62 99%, 95% respectively
Quarter no. 2 (April–June) k3ma: 0.76 90%
Quarter no. 3 (July–September) k3ma: 2.14 95%
Quarter no. 4 (October–December) k3mb: 1.31 72%
Tourist route in military object Quarter no. 1 (January–March) k3ma: 0.62, k3mb: 1.40 89%, 82% respectively
Quarter no. 2 (April-June) k3ma: 0.76 72%
Quarter no. 3 (July–September) k3ma: 2.14 72%
Quarter no. 4 without recommendation k3m Too high difference of estimation

Explanation: ZG—mining plant, k1m – monthly correction factor, k3m – quarterly correction factor, k3ma – quarterly correction factor for naturally ventilated facilities, k3mb – quarterly correction factor for facilities with mechanical ventilation systems, k3mc – averaged quarterly correction factor for all underground facilities, k1ma – monthly correction factor for naturally ventilated facilities well insulated from the atmosphere, k1mb – monthly correction factor for non-insulated facilities, k1mc – averaged monthly correction factor for underground facilities, k1md – monthly correction factor for facilities with mechanical ventilation systems