Skip to main content
. 2024 Jul;53(7):1569–1577. doi: 10.18502/ijph.v53i7.16051

Table 3:

Sensitivity, specificity and the positive likelihood ratio and negative likelihood ratio of ELISA results for the prediction Geenius test results (n:144)

S/CO value Sensitivity Specificity PLR NLR
≥1.01 100.00 0.00 1.00
>7.03 100.00 93.55 15.50 0.00
>8.54 97.59 93.55 15.13 0.026
>13.16 97.59 98.39 60.51 0.024
>102 83.13 98.39 51.54 0.17

*PLR: The likelihood ratio for being positive, NLR: The likelihood ratio for being negative