Table 5:
Model | Hazard ratio (CI) | P value |
---|---|---|
Model 1: Crude CVVHDF/RCA3.0 vs CVVH/RCA2.2 | 0.31 (0.18–0.52) | <.001 |
Model 2: adjusted for sex and age | 0.31 (0.18–0.52) | <.001 |
Model 3: adjusted for sex, body weight, and age | 0.32 (0.19–0.54) | <.001 |
Model 4: adjusted for sex, body weight, age, and COVID-19 | 0.32 (0.19–0.54) | <.001 |
Model 5: adjusted for sex, body weight, age, COVID-19, and APACHE IV score. | 0.33 (0.20–0.55) | <.001 |
Frailty Cox proportional hazard models based on all CRRT circuits of the CVVH/RCA2.2 protocol group (n = 179) and the CVVHDF/RCA3.0 protocol group (n = 168), after exclusion of CRRT circuits ended because of procedures outside the ICU, machine errors, or the decision to cease CRRT. Body weight was entered per 10 kg increase.