Skip to main content
. 2024 Aug 2;3:107. doi: 10.1038/s44172-024-00254-9

Table 2.

Statistical testing results of the hold-out set with an additional four kidney samples using attenuation coefficient

(A)
Tissue Testing of the hold-out set using attenuation coefficient
Cortex Medulla Calyx Fat  Carcinoma
True Cortex 7418 306 2170 0 106
Medulla 6 9225 756 13 0
Calyx 2452 2612 1228 604 3104
Fat 1007 1418 775 6679 121
Carcinoma 7 4 2 13 9974
(B)
Tissue Accuracy Precision Recall F1 score
Cortex 87.89% 68.12% 74.18% 71.02%
Medulla 89.77% 68.01% 92.25% 78.29%
Calyx 75.05% 24.90% 12.28% 16.45%
Fat 92.10% 91.38% 66.79% 77.17%
Carcinoma 93.29% 74.96% 99.74% 85.60%

A: confusion matrix. B: performance metrics.