Skip to main content
. Author manuscript; available in PMC: 2025 Jan 1.
Published in final edited form as: Evid Based Pract Child Adolesc Ment Health. 2023 Nov 8;9(2):245–261. doi: 10.1080/23794925.2023.2272948

Table 5.

Area under the Curve (AUC) values, Optimal Cutoff Score, Sensitivity, Specificity, Positive Predictive Value (PPV), and Negative Productive Value (NPV) for the Parent Motor or Vocal Inventory of Tics (MOVeIT-14 and MOVeIT-10)* for identifying tic symptoms (n=199)

MOVeIT-14
value (95% CI**)
MOVeIT-10
value (95% CI**)
AUC 74.5% (67.9, 80.4%) 73.5% (66.8, 79.5%)
Optimal cutoff score >5 (>4, >7) >4 (>3, >5)
Sensitivity 89.8% (79.2, 96.2%) 86.4% (75.0, 94.0%)
Specificity 57.1% (48.5, 65.5%) 55.7% (47.1, 64.1%)
PPV 46.9% (41.7, 52.1%) 45.1% (40.0, 50.3%)
NPV 93.0% (86.0, 96.7%) 90.7% (83.5, 95.0%)
Accuracy 66.8% (59.8, 73.3%) 64.8% (57.7, 71.4%)
*

Motor or Vocal Inventory of Tics: 14-item=MOVeIT-14; 10-item=MOVeIT-10

**

CI: Confidence interval