Skip to main content
. 2024 May 14;25(8):e14392. doi: 10.1002/acm2.14392

TABLE 1.

Test case geometries for Acuros BV algorithm testing. Reproduced from IROC Houston's user guide. The source direction for this work corresponded with Varian's internal positive y‐axis (not positive z‐axis as detailed in the IROC Houston user's guide).

Test case Inner cube material “Cube” Outer cube material “BgBOX” 192Ir source center location Applicator
1 H2O H2O (0,0,0) cm None
2 H2O Air (0,0,0) cm None
3 H2O Air (7,0,0) cm None
4 H2O Air (0,0,0) cm WG shielded cylinder