Table 2. Optimal Cooling Rate Value for Temperature Measurement Point TC7.

cooling rate (°C/h) maximum optimal minimum
procedures      
step22 0.88 0.66 0.43
step23 0.57 0.42 0.27
step24 0.33 0.25 0.18
step25 0.21 0.15 0.09
step26 0.24 0.19 0.14
step27 0.38 0.26 0.15
step28 0.31 0.24 0.18
step29 0.37 0.29 0.20