Skip to main content
. 2024 Jul 5;6(7):000804.v3. doi: 10.1099/acmi.0.000804.v3

Table 7. Contamination of medical uniforms by blood.

Parameters ISO 22196 Medical uniforms Modification
Environmental 35 °C and >90 % RH 20–24 °C and 50 % RH Use 24 °C as this will accelerate drying and so present the worst-case for a technology to function under and 50 % RH.
Volume of droplet 400 µl 400 µl No modification.
Species used S. aureusE coli S. aureusE. coliPs. aeruginosaEn. hiraeA. baumannii Use additional species relevant to the medical field.
Suspending medium 1/500 NB Blood A more suitable suspending medium will be employed to more closely simulate the contamination event.
Contact times 24 h 24 h No modification.
Sample form Small coupons Small coupons No modification.
Recovery method Samples ‘extracted’ in a neutralizer Samples ‘extracted’ in a neutralizer No modification.