Skip to main content
. 2024 Aug 13;14:18826. doi: 10.1038/s41598-024-69802-9

Table 1.

Utilized polymer membrane development values for automotive networks.

Variable name Values
Selected base generated power value of the fuel system (Ppeak) 1.260 k Watts
Overall network production voltage in the fuel system (VPeak) 24.23Volts
Peak current produced from the polymer membrane fuel stack (IPeak) 52A
Overall air passing rate in the polymer membrane stack (Ipm) 419.897
Polymer membrane electrolyte generated gas constant value (R) 83.28956 [J mol−1 K−1]
Determined polymer membrane material Faraday constant (F) 91,624.5675 [C mol−1]
Oxygen reaction-based composition value for the polymer membrane 22.256%
The entire fuel utilization of the proposed polymer membrane stack 98.672%
H2 reaction decomposition rate for polymer membrane stack 98.891%
O2 reaction decomposition rate for polymer membrane stack 66.785%