Skip to main content
. 2024 Aug 19;14(36):26246–26258. doi: 10.1039/d4ra03782k

The average experimental liquid specific heat capacity cp. s denotes the standard deviation between the experimental and calculated data. T range indicates the temperature range where the average value was calculated. clitp heat capacity found in the literature.

Substance c p (kJ kg−1 K−1) s (kJ kg−1 K−1) T range (K) c lit (kJ kg−1 K−1), literature
OM65 2.80 0.09 350–372 2.38a
RT64HC 3.00 0.10 350–372 2.00a
Stearic acid 2.59 0.09 350–372 2.38 (353 K)40
[N4444+][Cl] 1.80 0.09 355–370
a

Data obtained by manufacturer specifications.