Skip to main content
. 2024 Mar 21;14:6827. doi: 10.1038/s41598-024-57610-0

Table 1.

PV system characteristics.

Parameters Values
The Peak Power of the PV panel (W) 213.15
Open circuit voltage VOC (V) 36.3
Short circuit current ISC (A) 7.84
The voltage corresponding to the maximum power VMP (V) 29
The current corresponding to the maximum power IMP (A) 7.35
Parallel strings (NP) 2
Number of cells associated in Series (NS) 2
Input capacitor C1 100 µF
Output capacitor C2 100 µF
Inductor L 2 mH
Restore load R 25Ω
Frequency f 20 kHz
Solver 1 e-6
Sample time Ode 45