The specifications and description of the selected building type: R2 category located in Tirana region.

Base scenario case Proposed case
Net area 80 m2 80 m2
Height 2.4 m 2.4 m
Volume 192 m3 192 m3
Total Envelope Area 180 m2 180 m2
Climatic zone A HDD<1500 HDD<1500
Heating/Cooling system Inverter-Split Inverter-Split
Energy carrier used for DHW Electricity Electricity
Electricity price (€/kWh) 0.1–0.25 0.1–0.25
Wall's heat transfer coefficient (W/m2K) 1.87 0.38–0.4 [30]
Window's heat transfer coefficient (W/m2K) 5.2 2.0–2.2 [30]
Roof's heat transfer coefficient (W/m2K) 1.0 0.35–0.38 [30]
Floor's heat transfer coefficient (W/m2K) 1.2 0.5 [30]
Lighting system Incandescent LED
RES application NA PV and SWH