Skip to main content
. 2024 Aug 13;14(16):1765. doi: 10.3390/diagnostics14161765

Table 4.

Sensitivity analyses of the testing samples for detecting DR and STDR.

Statistic Analysis for Detecting DR Analysis for Detecting STDR
Value Lower Bound (95%) Upper Bound (95%) Value Lower Bound (95%) Upper Bound (95%)
Correct classification 1.000 1.000 1.000 0.757 0.707 0.807
Misclassification 0.000 0.000 0.000 0.243 0.193 0.293
Sensitivity 1.000 0.968 1.000 0.532 0.392 0.666
Specificity 1.000 0.967 1.000 0.802 0.746 0.847
False positive rate 0.000 0.000 0.000 0.198 0.148 0.249
False negative rate 0.000 0.000 0.000 0.468 0.331 0.605
Prevalence 0.514 0.456 0.572 0.165 0.122 0.209
Positive Predictive Value 1.000 1.000 1.000 0.347 0.237 0.457
Negative Predictive Value 1.000 1.000 1.000 0.896 0.855 0.937

Abbreviations: DR—diabetic retinopathy; STDR—sight threatening diabetic retinopathy.