Parameters of Postjunctional Electrical Responses to EFS in WT, Veh-Treated klotho Mice, and EPZ-treated klotho Mice

EFS frequency Parameter WT
Veh
klotho
Veh
klotho EPZ P (WT Veh vs klotho Veh) P (WT Veh vs klotho EPZ) P (klotho veh vs klotho EPZ)
5 Hz Fast IJP 2.214 ± 0.6908 [0.5573; 1.510; 3.939] (9) 0.2890 ± 0.1692 [0.000; 0.000; 0.2654] (16) 0.3230 ± 0.1328 [0.000; 0.09462; 0.7452] (10) .001 .0033 .9971
Slow IJP 0.9944 ± 0.3020 [0.3431; 0.8320; 1.937] (8) 0.3828 ± 0.1998 [0.000; 0.000; 0.5364] (16) 0.3856 ± 0.2173 [0.000; 0.000; 0.7044] (10) .1839 .2436 > .9999
Fast + slow IJP 3.919 ± 1.305 [1.113; 2.349; 5.971] (9) 0.6323 ± 0.3415 [0.000; 0.000; 0.6194] (17) 0.7087 ± 0.3354 [0.000; 0.2506; 1.155] (10) .0031 .0099 .9959
10 Hz Fast IJP 5.227 ± 1.564 [1.749; 2.836; 9.272] (9) 1.375 ± 0.4402 [0.04487; 0.7626; 2.098] (16) 2.193 ± 0.5199 [1.199; 1.702; 2.646] (10) .0061 .0596 .7472
Slow IJP 3.763 ± 1.083 [1.050; 2.606; 6.093] (9) 1.456 ± 0.4640 [0.07564; 0.5321; 2.768] (15) 3.239 ± 0.7012 [1.602; 2.789; 4.039] (10) .0693 .8804 .1725
Fast + slow IJP 8.990 ± 2.604 [3.351; 4.577; 14.54] (9) 2.580 ± 0.7995 [0.2551; 1.111; 4.958] (15) 4.340 ± 0.4327 [3.356; 3.807; 5.365] (9) .0068 .0982 .6403
20 Hz Fast IJP 5.393 ± 1.282 [3.355; 4.720; 6.090] (8) 1.801 ± 0.6435 [0.000; 0.5436; 2.647] (15) 3.860 ± 1.026 [1.047; 3.616; 6.573] (10) .0284 .5399 .233
Slow IJP 7.926 ± 2.614 [2.818; 3.843; 12.47] (9) 2.857 ± 4.228 [0.04420; 0.5175; 5.418] (16) 5.932 ± 1.611 [1.205; 5.260; 9.252] (10) .0895 .7184 .3689
Fast + slow IJP 11.24 ± 2.259 [7.369; 7.788; 18.38] (8) 4.004 ± 1.369 [0.000; 0.8982; 9.647] (15) 9.792 ± 1.494 [5.857; 10.67; 13.32] (10) .0128 .8409 .0357

NOTE. Responses to square wave electrical pulses (0.3 ms; 5–20 Hz for 1 second; supramaximal voltage) are expressed as areas under the curve (mV) (ie, the areas segmented by RMP before electrical simulation and the subsequent junction potentials). Data are mean ± and [median + interquartile range] from 3 WT, 6 klotho Veh, and 5 klotho EPZ. The number of responses that were analyzed are located in parentheses.

EFS, electrical field stimulation; EPZ, EPZ6438; IJP, inhibitory junction potential; Veh, vehicle; WT, wild-type.