Skip to main content
. 2024 Aug 19;15:1436554. doi: 10.3389/fphar.2024.1436554

TABLE 6.

Results of testing age and formulation effects on the composite acceptability endpoint (p-values are provided).

Comparison Age Formulation Interaction age-by-formulation
Mini-tablets vs. syrup 0.5985 <0.0001 0.2256
Mini-tablets vs. round tablet Not interpretable Not interpretable 0.0863
Mini-tablets vs. oblong tablet Not interpretable Not interpretable 0.0007
Round tablet vs. syrup 0.3325 0.0050 0.6580
Oblong tablet vs. syrup 0.0242 <0.0001 0.7331
Oblong tablet vs. round tablet Not interpretable Not interpretable 0.0300

In case of a significant age-by-formulation interaction (p < 0.1) overall age and overall formulation results are not interpretable