Table 1.
Product | Method | Company | Target | Characteristics | Reference |
---|---|---|---|---|---|
VIRAPID® TULAREMIA | LFA a | Vircell | LPS b | 99.1% sensitivity and 98.6% specificity | (Kılıç et al., 2012; Chaignat et al., 2014) |
BADD Tularemia Biowarfare Detection Test Kit | LFA a | ADVNT biotechnologies | Not reported | 1.48 x 106 cfu/mL of LoD c | https://advnt.org |
Raid™ 8 | LFA a | Alexeter Technologies | Not reported | 1.6 x 106 cfu/mL of LoD c | https://www.alexeter.com |
Tularemia BioThreat Alert® Kit | LFA a | Tetracore | Not reported | 1.0 x 107~ 1 x108 cfu/mL of LoD c | (Pillai et al., 2020) |
SERION ELISA classic Francisella tularensis | ELISA | SERION diagnostics | LPS b | 86.3% sensitivity and 95.5% specificity | (Yanes et al., 2018) |
Tularemia test kit Biotoxis | RT-PCR | Bertin | Not reported | 90.32~96.55% sensitivity, 1,000 cfu/L LoD/49 copies |
(Hennebique et al., 2020) |
Francisella tularensis RT-PCR Kit | RT-PCR | BioPerfectus | Not reported | 5 copies/reaction of LoD c | https://www.bioperfectus.com |
Lateral Flow Assay.
Lipopolysaccharide.
Limit of Detection.