Skip to main content
. 2024 Aug 30;40(4):287–320. doi: 10.3393/ac.2023.00871.0124

Table 3.

Short- and long-term effectiveness of stapled hemorrhoidopexy with high-volume stapler devices for hemorrhoidal disease: the results of 3 retrospective studies

Study Type of study Study size Prolapse grade Stapler device Follow-up (mo) Primary outcome
Reboa et al. [247] (2016) Multicenter, retrospective 621 3, 4 CPH34 HVa 12 Residual hemorrhoidal prolapse, 1.8%
Recurrent hemorrhoidal prolapse, 1.9%
Wei et al. [248] (2022) Single-center, retrospective 125 3 TST STARR Plusb 57.3c Recurrence rate, 5.2%
Sturiale et al. [236] (2023) Single-center, retrospective 59 2–4 TST STARR Plusb 70.5c Recurrence rate, 5.1%
a

Frankenman International Ltd.

b

Touchstone International Medical Science Co Ltd.

c

Median.