Skip to main content
. 2024 Apr 22;326(6):R567–R577. doi: 10.1152/ajpregu.00036.2024

Table 2.

Individual best-fit power-duration relationship parameters

Subject Best-Fit Model CP, W SEE, W CV, % W′, kJ SEE, kJ CV, %
1 Hyperbolic 189 1.6 1 23.0 1.5 7
2 Hyperbolic 157 2.8 2 23.0 1.0 4
3 Hyperbolic 152 2.2 1 13.2 1.3 10
4 1/Time 150 3.2 2 22.9 1.1 5
5 Work time 150 6.4 4 14.3 3.3 23
6 Work time 173 1.2 1 17.6 0.5 3
7 Hyperbolic 144 2.6 2 16.0 1.8 11
8 1/Time 121 4.2 3 15.6 1.2 8
9 Hyperbolic 141 2.8 2 29.8 1.7 6
10 Hyperbolic 157 2.6 2 31.4 1.7 5
11 Hyperbolic 128 1.7 1 10.5 1.3 13
12 Hyperbolic 144 0.9 1 11.9 0.6 5
13 Hyperbolic 181 4.6 3 14.0 2.9 20
Mean 153 3 2 19 2 9
SD 19 2 1 7 1 6

CP, critical power; CV, coefficient of variation; SEE, standard error of the estimate.