Skip to main content
. 2024 Aug;45(8):1044–1052. doi: 10.3174/ajnr.A8272

Table 4:

DL model performance on prospective MR imaging and CT test set

Model ROC-AUC Accuracy Sensitivity Specificity
MR imaging 0.7967 (0.0335) 0.7774 (0.0367) 0.7286 (0.1849) 0.8462 (0.1216)
CT 0.8051 (0.0377) 0.8080 (0.0299) 0.8615 (0.1131) 0.7500 (0.1054)