Skip to main content
. 2024 Sep 10;14:21098. doi: 10.1038/s41598-024-72069-9

Table 4.

Association between 4 h urinary creatinine clearance at T3 and creatinine clearance estimated by kinetic formula (D3Ccreat) at T3.

Formula Bias Precision Accuracy
MPE R2 RMSE P15 P30
Cockcroft-Gault (ml/min) 43 0.19 49 12 16
D3C (ml/min) 17 0.07 40 12 24

The Cockcroft-Gault at T3 is provided as reference.

MPE Mean Prediction Error (ml/min), RMSE Root Mean Squared Error (ml/min), R2 the R2-value calculated with linear regression, p15/p30 the percentage of points that fall within 15%/30% of the outcome.