Skip to main content
. 2024 Jul 18;4(2):e835. doi: 10.52225/narra.v4i2.835

Table 3.

Mean blood absorption rate and mean area of pad wetted with labor blood

Sample Blood absorption, mean±SD
(mL/min)
Area of the blood-wetted pad,
mean±SD (cm2)
S1 14.7±0.7 162.0±5.3
S2 11.2±0.8 142.3±4.0
S3 13.9±0.1 58.70±1.5
S4 9.9±0.9 135.7±5.5
SAP+cellulose rayon 17.4±0.2 198.3±8.5
Zeolite+cellulose rayon 18.3±0.3 218.6±7.7
SAP+zeolite+cellulose rayon 25.8±3.3 317.6±11.2

SAP: super absorbent polymer