Table 1.
Summary of input parameters and corresponding dimensionless numbers of the simulations presented in the database. In detail: dp1 represents the diameter of microplastics, dp2 is the diameter of biogenic particles, np1 denotes the number density of microplastics, np2 indicates the number density of biogenic particles; Stλ1 is the Stokes number for microplastics, Stλ2 is the Stokes number for biogenic particles; Φv represents the mixture volume fraction, and α is the coagulation efficiency. For a comprehensive description of these parameters, refer to Section 4.
| Case | dp1 [m] | dp2 [m] | np1 [prt/m3] | np2 [prt/m3] | Stλ1 | Stλ2 | Φv | α |
|---|---|---|---|---|---|---|---|---|
| 1 | 1.5‧10−4 | 7.5‧10−5 | 1.0‧107 | 1.0‧107 | 1.92‧10−4 | 7.20‧10−5 | 1.99‧10−5 | 1/3 |
| 2 | 1.5‧10−4 | 7.5‧10−5 | 1.0‧107 | 1.0‧107 | 1.92‧10−4 | 7.20‧10−5 | 1.99‧10−5 | 2/3 |
| 3 | 1.5‧10−4 | 7.5‧10−5 | 1.0‧107 | 1.0‧107 | 1.92‧10−4 | 7.20‧10−5 | 1.99‧10−5 | 3/3 |
| 4 | 1.5‧10−4 | 7.5‧10−5 | 2.5‧107 | 5.0‧107 | 1.92‧10−4 | 7.20‧10−5 | 5.52‧10−5 | 1/3 |
| 5 | 1.5‧10−4 | 7.5‧10−5 | 2.5‧107 | 5.0‧107 | 1.92‧10−4 | 7.20‧10−5 | 5.52‧10−5 | 2/3 |
| 6 | 1.5‧10−4 | 7.5‧10−5 | 2.5‧107 | 5.0‧107 | 1.92‧10−4 | 7.20‧10−5 | 5.52‧10−5 | 3/3 |
| 7 | 3.0‧10−4 | 1.5‧10−4 | 1.0‧107 | 1.0‧107 | 7.68‧10−4 | 2.90‧10−4 | 1.59‧10−5 | 1/3 |
| 8 | 3.0‧10−4 | 1.5‧10−4 | 1.0‧107 | 1.0‧107 | 7.68‧10−4 | 2.90‧10−4 | 1.59‧10−5 | 2/3 |
| 9 | 3.0‧10−4 | 1.5‧10−4 | 1.0‧107 | 1.0‧107 | 7.68‧10−4 | 2.90‧10−4 | 1.59‧10−5 | 3/3 |