Skip to main content
. 2024 Aug 20;56:110850. doi: 10.1016/j.dib.2024.110850

Table 1.

Summary of input parameters and corresponding dimensionless numbers of the simulations presented in the database. In detail: dp1 represents the diameter of microplastics, dp2 is the diameter of biogenic particles, np1 denotes the number density of microplastics, np2 indicates the number density of biogenic particles; Stλ1 is the Stokes number for microplastics, Stλ2 is the Stokes number for biogenic particles; Φv represents the mixture volume fraction, and α is the coagulation efficiency. For a comprehensive description of these parameters, refer to Section 4.

Case dp1 [m] dp2 [m] np1 [prt/m3] np2 [prt/m3] Stλ1 Stλ2 Φv α
1 1.5‧10−4 7.5‧10−5 1.0‧107 1.0‧107 1.92‧10−4 7.20‧10−5 1.99‧10−5 1/3
2 1.5‧10−4 7.5‧10−5 1.0‧107 1.0‧107 1.92‧10−4 7.20‧10−5 1.99‧10−5 2/3
3 1.5‧10−4 7.5‧10−5 1.0‧107 1.0‧107 1.92‧10−4 7.20‧10−5 1.99‧10−5 3/3
4 1.5‧10−4 7.5‧10−5 2.5‧107 5.0‧107 1.92‧10−4 7.20‧10−5 5.52‧10−5 1/3
5 1.5‧10−4 7.5‧10−5 2.5‧107 5.0‧107 1.92‧10−4 7.20‧10−5 5.52‧10−5 2/3
6 1.5‧10−4 7.5‧10−5 2.5‧107 5.0‧107 1.92‧10−4 7.20‧10−5 5.52‧10−5 3/3
7 3.0‧10−4 1.5‧10−4 1.0‧107 1.0‧107 7.68‧10−4 2.90‧10−4 1.59‧10−5 1/3
8 3.0‧10−4 1.5‧10−4 1.0‧107 1.0‧107 7.68‧10−4 2.90‧10−4 1.59‧10−5 2/3
9 3.0‧10−4 1.5‧10−4 1.0‧107 1.0‧107 7.68‧10−4 2.90‧10−4 1.59‧10−5 3/3