The main parameters of rectifier.

Circuit Parameters/Symbols Numerical Value
The effective value of the input phase voltage/Um 220 V
PFC converter inductor/La 0.3 mH
PFC converter capacitor/Ca 2000 μF
SPWM inverter inductor/Las 1 mH
SPWM inverter capacitor/Cas 10 μF
Grid-side voltage frequency/fv 50 Hz
Phase-shifting transformer operating frequency/f 400 Hz
Phase-shifting transformer turns ratio/N0:N1:N2 1:6/3:(326)/6
Load resistance/R 20 Ω
Load filtering inductor/L 15 mH