Table 5.
Composite Type |
σu (Expt.) Base (MPa) |
σu (FEM) Base (MPa) |
Deviation (%) | σu (Expt.) pH8 (MPa) | σu (FEM) pH8 (MPa) | Deviation (%) |
---|---|---|---|---|---|---|
A(0°) | 83.6 | 83.60 | 0 | 68.6 | 68.6 | 0 |
A(45°) | 28.5 | 28.5 | 0 | 36.3 | 36.1 | 0.55 |
A(90°) | 12.0 | 12.0 | 0 | 11.46 | 11.31 | 1.31 |
B(0°) | 89.1 | 89.1 | 0 | 88.5 | 88.5 | 0 |
C(0°) | 299 | 295.35 | 1.22 | 270 | 270 | 0 |
D(0°) | 317 | 317 | 0 | 228 | 228 | 0 |