Table 2.
Box-Behnken design response surface methodology design scheme and test results.
| Run | X1 (Power) W |
X2 (Time) min |
X3 (Temperature) ℃ |
Y1 (Te-A) mg/g |
Y2 (Ta-A) mg/g |
|---|---|---|---|---|---|
| 1 | 150 | 40 | 50 | 2.74 | 1.12 |
| 2 | 150 | 20 | 50 | 2.64 | 1.11 |
| 3 | 150 | 30 | 40 | 2.42 | 0.97 |
| 4 | 150 | 30 | 60 | 2.28 | 0.98 |
| 5 | 200 | 30 | 50 | 2.81 | 1.10 |
| 6 | 200 | 30 | 50 | 2.35 | 0.99 |
| 7 | 200 | 20 | 60 | 2.65 | 0.93 |
| 8 | 200 | 30 | 50 | 2.15 | 0.83 |
| 9 | 200 | 40 | 40 | 2.50 | 1.12 |
| 10 | 200 | 20 | 40 | 2.31 | 0.92 |
| 11 | 200 | 30 | 50 | 2.70 | 1.08 |
| 12 | 200 | 30 | 50 | 2.68 | 1.16 |
| 13 | 200 | 40 | 60 | 2.84 | 1.15 |
| 14 | 250 | 20 | 50 | 2.39 | 1.01 |
| 15 | 250 | 30 | 60 | 2.42 | 1.18 |
| 16 | 250 | 30 | 40 | 2.88 | 1.19 |
| 17 | 250 | 40 | 50 | 2.43 | 1.12 |