TABLE 2.
Recommended parameters for irrigation with a 5 mL syringe (20) | |||
---|---|---|---|
Cannula | Type | Plunger force (N) | Irrigant delivery gauge duration (s) |
25 G | Side-vented | 10 | ≥21 |
25 G | Open-vented | 10–20 | ≥18 |
30 G | Side-vented | 10–40 | ≥38 |
30 G | Open-vented | 10–40 | ≥30 |
N: Newton, G: Gauge