Skip to main content
. 2024 Aug 12;10(18):e35998. doi: 10.1016/j.heliyon.2024.e35998

Table 5.

The Results of the First-time Inspection Accuracy.

Number of optical fibers 1st Set 2nd Set 3rd Set 4th Set 5th Set 6th Set 7th Set 8th Set
12 100.0% 91.6% 100.0% 100.0% 100.0% 100.0% 91.6% 100.0%
36 100.0% 100.0% 97.2% 100.0% 100.0% 94.4% 100.0% 97.2%
64 100.0% 96.9% 100.0% 100.0% 98.4% 100.0% 100.0% 98.4%