Skip to main content
. 2024 Apr 7;77(2):235–242. doi: 10.5173/ceju.2023.266

Table 4.

Logistic regression model predicting postoperative absence of antegrade ejaculation

Variable Univariate analysis Multivariate analysis
OR (95% C.I.) p-value OR (95% C.I.) p-value
Age 1.08 (1.02–1.14) 0.01 1.08 (1.01–1.16) 0.03
Prostate volume >30 ml 5.56 (1.19–26.07) 0.03 4.36 (0.76–25.04) 0.09
Presence of median lobe 3.24 (1.04–10.13) 0.04 0.26 (0.02–3.62) 0.31
Preoperative Qmax 1.02 (0.89–1.02) 0.89
Preoperative PVR 0.99 (0.98–1.00) 0.36
Operative time 1.06 (1.01–1.10) 0.01 1.07 (0.97–1.17) 0.14

OR – odds ratio; C.I. – confidence interval; Qmax – maximum flow rate; PVR – post-void residual