Results from measurements and simulations in the six areas investigated. The direct dose rate was obtained by multiplying the measured count rate by the dose conversion factor of 0.037 (µSv/h)/(counts/s). For the measured and simulated dose rates, see the following chapter. The quoted uncertainties are statistical only.

Location Tag Run Time
[s]
Count Rate [cps] Average Dose Rate
(Direct)
[µSv/h]
Average Dose Rate
(Measured)
[µSv/h]
Dose Rate
(Simulation) [µSv/h]
ambient, in sources region a 110 5.97 0.22 ± 0.009 0.13 ± 0.005 -
amid 152Eu, 137Cs, 60Co b 40 7.23 0.27 ± 0.016 0.17 ± 0.010 -
137Cs, 60Co c 110 12.43 0.46 ± 0.012 0.44 ± 0.012 ≈0.4
241Am d 70 7.59 0.28 ± 0.012 0.18 ± 0.008 ≈0.12
152Eu e 120 7.39 0.27 ± 0.009 0.18 ± 0.006 ≈0.1
ambient, far from sources f 80 4.04 0.15 ± 0.008 0.07 ± 0.004 -