. 2024 Sep 13;26(10):euae240. doi: 10.1093/europace/euae240

Table 2.

Metrics for the premature ventricular contraction PVC and dual-rhythm models with differences on the algorithm development data set and external validation data set

Accuracy (95% CI) Precision (95% CI) Recall (95% CI) specificity (95% CI) AUC_ROC (95% CI) F1-scorea (95% CI)
Algorithm development data set
 PVC model 0.78 (0.74–0.80) 0.59 (0.52–0.67) 0.79 (0.72–0.79) 0.76 (0.71–0.81) 0.88 (0.85–0.92) 0.68 (0.62–0.74)
 Dual-rhythm model 0.87 (0.84–0.90) 0.92 (0.91–1.00) 0.63 (0.55–0.72) 0.98 (0.98–1.00) 0.92 (0.89–0.94) 0.75 (0.69–0.81)
 Differences 0.10 (0.07–0.15) 0.34 (0.28–0.42) −0.17 (−0.22 to −0.12) 0.23 (0.18–0.28) 0.04 (0.01–0.06) 0.07 (0.01–0.14)
P-value < 0.01 < 0.01 < 0.01 < 0.01 0.02 0.03
External validation data set
 PVC model 0.74 (0.70–0.79) 0.55 (0.47–0.63) 0.87 (0.81–0.95) 0.68 (0.62–0.75) 0.86 (0.82–0.90) 0.68 (0.60–0.74)
 Dual-rhythm model 0.84 (0.81–0.89) 0.73 (0.65–0.83) 0.80 (0.74–0.90) 0.87 (0.82–0.92) 0.91 (0.88–0.95) 0.77 (0.70–0.83)
 Differences 0.11 (0.06–0.16) 0.18 (0.11–0.27) −0.05 (−0.16 to −0.04) 0.19 (0.12–0.26) 0.03 (0.01–0.09) 0.09 (0.02–0.17)
P-value < 0.01 < 0.01 0.03 <0.01 0.03 0.03

AUC-ROC, area under the curve for the receiver operating characteristic; CI, confidence interval; PVC, premature ventricular contraction.

aF1 score was calculated as follows: F1-score = 2 × Precision × Recall/(Precision + Recall).