Abstract
Two aspects of handwashing in hospital were considered. A study was carried out to examine the contamination of bar soap and containers, and the use of antiseptic soaps in reducing the resident flora of the skin. Swabs were collected from soap dishes on six wards and from a bacteriology laboratory on four consecutive days. The unmedicated bar soap was replaced by bar soap containing 2·5% povidone-iodine, and further swabs were collected over a period of seven days. Ninety-two isolates from 48 samples were obtained when unmedicated bar soap was used, and nine isolates from 42 samples when povidone-iodine (Betadine) soap was substituted. The number of organisms recovered when povidone-iodine soap was used was much reduced, and Pseudomonas spp were recovered in low numbers on only one occasion.
Six laboratory workers took part in a study to compare bar soap with other agents—povidone-iodine soap, povidone-iodine surgical scrub, povidone-iodine alcoholic solution, chlorhexidine surgical scrub, and alcoholic chlorhexidine. Samples were collected after standard washes and after surgical gloves had been worn for 90 minutes. The effect of multiple washes was assessed by samples collected after six washes with the agent under study (three per day) followed by 90 minutes wearing surgical gloves. The average percentage reduction in normal flora obtained indicated that alcoholic chlorhexidine was superior to the other agents.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- ANDERSON K. The contamination of hexachlorophene soap with Pseudomonas pyocyanea. Med J Aust. 1962 Sep 22;49(2):463–465. doi: 10.5694/j.1326-5377.1962.tb20451.x. [DOI] [PubMed] [Google Scholar]
- Bassett D. J. Causes and prevention of sepsis due to Gram-negative bacteria. Common-source outbreaks. Proc R Soc Med. 1971 Sep;64(9):980–986. doi: 10.1177/003591577106400944. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bruun J. N., Solberg C. O. Hand carriage of gram-negative bacilli and Staphylococcus aureus. Br Med J. 1973 Jun 9;2(5866):580–582. doi: 10.1136/bmj.2.5866.580. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Casewell M., Phillips I. Hands as route of transmission for Klebsiella species. Br Med J. 1977 Nov 19;2(6098):1315–1317. doi: 10.1136/bmj.2.6098.1315. [DOI] [PMC free article] [PubMed] [Google Scholar]
- LOWBURY E. J., LILLY H. A. Disinfection of the hands of surgeons and nurses. Br Med J. 1960 May 14;1(5184):1445–1450. doi: 10.1136/bmj.1.5184.1445. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lowbury E. J., Lilly H. A., Ayliffe G. A. Preoperative disinfection of surgeons' hands: use of alcoholic solutions and effects of gloves on skin flora. Br Med J. 1974 Nov 16;4(5941):369–372. doi: 10.1136/bmj.4.5941.369. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mitchell R. G., Hayward A. C. Postoperative urinary-tract infections caused by contaminated irrigating fluid. Lancet. 1966 Apr 9;1(7441):793–795. doi: 10.1016/s0140-6736(66)91866-6. [DOI] [PubMed] [Google Scholar]
- Morse L. J., Williams H. L., Grenn F. P., Jr, Eldridge E. E., Rotta J. R. Septicemia due to Klebsiella pneumoniae originating from a hand-cream dispenser. N Engl J Med. 1967 Aug 31;277(9):472–473. doi: 10.1056/NEJM196708312770906. [DOI] [PubMed] [Google Scholar]