TABLE I.
Source | Typical bandwidth ( or , FWHM) (%) | Typical pulse duration |
---|---|---|
Si 111 monochromator | <0.01 | Continuous |
Cu anode (K ) with multilayer mirrorsa | 5 | Continuous |
Synchrotron multilayer monochromators (CHESS)54 | 0.6–1.3 | Continuous |
Synchrotron undulator (ESRF ID-09)55 | 1–3 | ps |
Synchrotron dual undulators (BioCARS)56 | 5.5 | ps |
SASE at XFELs57 | 0.1–0.3 | fs |
Pink SSX (Pohang)58 | 1.2 | fs |
SwissFEL pink59 | 1.8–2.2 | fs |
Inverse Compton sources (MuCLS)60 | 3 | Continuous |
Compact femtosecond Compton sources (CXLS)61 | 0.1–5 | fs |
Compact x-ray light sourceb | 3, 10 | fs |
Betatron source62 | <100 | fs |
Based on personal communication with Dr. J. Graf, Oncoatec (Bruker).
Based on personal communication with Dr. W. G. Graves, Arizona State University.