Skip to main content
. 2024 Sep 25;14(19):2123. doi: 10.3390/diagnostics14192123

Table 4.

Diagnostic values of the MSRA-5 and MSRA-7 with respect to different sarcopenia operational criteria.

Risk of Sarcopenia
Se Sp PPV NPV Acc AUC (95% CI) p-Value
EWGSOP2 MSRA-5 84.62 32.52 11.70 95.24 37.50 0.76 (0.64–0.87) 0.003 *
MSRA-7 92.31 21.95 11.11 96.43 28.68 0.73 (0.61–0.85) 0.007 *
AWGS-2019 MSRA-5 88.89 33.90 17.02 95.24 41.18 0.68 (0.58–0.79) 0.013 *
MSRA-7 94.44 22.88 15.74 96.43 32.35 0.67 (0.55–0.79) 0.019 *
IWGS MSRA-5 81.82 32.00 9.57 95.24 36.03 0.67 (0.54–0.80) 0.060
MSRA-7 90.91 20.80 9.17 96.30 26.47 0.65 (0.50–0.79) 0.111

Values expressed as percentages. Acc: accuracy. AUC: area under the receiver operating characteristic curve. AWGS: Asian Working Group on Sarcopenia. CI: confidence interval. EWGSOP2: Revised European Working Group of Sarcopenia in Older People. IWGS: International Working Group on Sarcopenia. MSRA: Mini Sarcopenia Risk Assessment. PPV: positive predictive value. NPV: negative predictive value. Se: sensitivity. Sp: specificity. * p value < 0.05.