Skip to main content
. 2024 Sep 28;13(19):3100. doi: 10.3390/foods13193100

Table 1.

Inline measurements of pH and conductivity during recirculation of concentrated skim milk solutions at 30% (w/w) total solids at a starting pH of 6.1, 6.3, 6.5, and 6.7. Measured changes (∆) in these parameters are shown. The abbreviations ‘t0’ and ‘t90’ indicate the measurements at the start (0 min) and end (90 min) of the fouling experiment.

pH Conductivity (mS/cm)
t0 t90 Cooled to 25 °C
after Run
∆ during Run ∆ 0–40 Min ∆ 40–90 Min t0 t90 Cooled to 25 °C
after Run
∆ during Run ∆ 0–40 min ∆ 40–90 min
6.1 5.70 a ± 0.13 6.00 a ± 0.00 0.36 a ± 0.08 0.34 a ± 0.08 0.02 a ± 0.00 8.09 a ± 0.07 9.40 a ± 0.08 8.21 a ± 0.01 1.31 a ± 0.01 0.87 a ± 0.69 0.04 a ± 0.01
6.3 5.93 b ± 0.00 6.20 b ± 0.00 0.36 a ± 0.01 0.30 a ± 0.01 0.06 a ± 0.00 8.09 a ± 0.00 9.24 b ± 0.00 8.25 a ± 0.00 1.15 b ± 0.00 0.57 a ± 0.03 0.01 a ± 0.00
6.5 6.11 c ± 0.07 6.36 b ± 0.09 0.36 a ± 0.02 0.31 a ± 0.01 0.05 a ± 0.03 8.04 a ± 0.02 9.18 b ± 0.06 8.24 a ± 0.04 1.14 b ± 0.08 0.41 a ± 0.22 0.07 a ± 0.03
6.7 6.25 d ± 0.01 6.58 c ± 0.04 0.38 a ± 0.01 0.32 a ± 0.00 0.06 a ± 0.01 8.07 a ± 0.05 9.09 c ± 0.02 8.23 a ± 0.02 1.02 c ± 0.07 0.58 a ± 0.07 0.06 a ± 0.01

Results are the means of data from two independent trials. Mean values within a column not sharing a common superscript letter differ significantly (p < 0.05).