Table 1.

Corrosion testing AE acquisition parameters setup.

Acquisition Parameters Value
Threshold 30 dB
Analogue Filter 20 kHz–1 MHz
Digital Filter -
Sample Rate 10 MSPS
Pre-Trigger 250 μ
Length 15 k samples
HDT 800 μs
HLT 800 μs
PDT 400 μs
Maximum Duration 99 ms