Table 1. Investigated numerical aspects of the cantilever deep beam with a discretization of 20,402 subvolumes.
SIMP method | |||
---|---|---|---|
Analysis | Sensitivity filter | Density filter | No filter |
Compliance (J) | 88.12 | 91.02 | 87.90 |
Filter radius | 0.71 | 0.71 | 0 |
Number of iterations | 368 | 577 | 391 |
Processing time ( sparse) | 1min 6s | 1min 58s | 1min 3s |
Processing time ( fsparse) | 1min 5s | 1min 38s | 1min 10s |
RAMP method | |||
---|---|---|---|
Analysis | Sensitivity filter | Density filter | No filter |
Compliance (J) | 85.86 | 87.69 | 84.49 |
Filter radius | 0.71 | 0.71 | 0 |
Number of iterations | 397 | 614 | 451 |
Processing time ( sparse) | 1min 1s | 1min 38s | 1min 16s |
Processing time ( fsparse) | 1min 3s | 1min 41s | 1min 13s |