Table 1.
Characteristics of the study participants
| Eyes with MRNF (n = 15) |
Contralateral eyes without MRNF (n = 15) | Control eyes (n = 15) |
P # | P* | |
|---|---|---|---|---|---|
| Spherical error | -9.17 ± 6.13 | -3.33 ± 3.70 | -9.37 ± 5.94 | 0.003 | 0.45 |
| range | -20.75, 0.00 | -12.00, 1.50 | -21.00, 0.00 | ||
| Cylindrical error | -2.00 (-2.25, -1.00) † | -1.13 ± 0.75 | -1.55 ± 1.10 | 0.04 | 0.53 |
| range | -5.50, 0.00 | -2.50, 0.00 | -4.25, -0.25 | ||
| SER | -10.10 ± 6.36 | -3.90 ± 3.94 | -10.14 ± 6.11 | 0.002 | 0.80 |
| range | -21.25, 0.00 | -13.25, 0.75 | -21.5, -0.13 | ||
| BCVA, logMAR | 0.40 (0, 0.7) † | -0.02 ± 0.05 | 0.04 ± 0.09 | 0.002 | 0.01 |
| range | -0.08, 1.30 | -0.18, 0.00 | 0.00, 0.30 | ||
| IOP, mmHg | 13.20 ± 2.80 | 13.36 ± 3.08 | 15.27 ± 2.79 | 0.74 | 0.05 |
| range | 10.0, 19.9 | 9.0, 19.0 | 12.0, 20.5 | ||
| Axial length, mm | 27.65 ± 2.64 | 25.22 ± 1.51 | 27.47 ± 2.42 | 0.003 | 0.58 |
| range | 23.39, 32.91 | 23.14, 28.33 | 24.38, 33.1 | ||
| Corneal K readings, D | 42.78 ± 1.76 | 42.87 ± 1.87 | 43.85 ± 1.53 | 0.46 | 0.11 |
| range | 39.68, 45.10 | 39.38, 45.55 | 41.45, 46.10 | ||
| CCT, µm | 560.5(517.0,566.0)† | 545.5(511.8,564.5) † | 530.5 ± 37.9 | 0.04 | 0.36 |
| range | 433, 584 | 430, 574 | 466, 588 | ||
| ACD, mm | 3.46 ± 0.26 | 3.49 ± 0.27 | 3.41 ± 0.26 | 0.11 | 0.69 |
| range | 2.88, 3.77 | 2.93, 3.84 | 2.99, 3.94 | ||
| Area1, (pixel)×104 | 137.15 ± 152.04 | - | |||
| Range | 4.60, 441.22 | ||||
| Area2, (pixel)×104 | 43.86 ± 38.09 | - | |||
| range | 4.29, 142.83 | ||||
| Df−m, µm | 399.77 ± 219.06 | - | |||
| range | 0, 728.87 |
#Comparison between eyes with MRNF and contralateral eyes without MRNF
*Comparison between eyes with MRNF and control eyes
†Median (P25–P75)
MRNF = Myelinated Retinal Nerve Fiber; BCVA = Best Corrected Visual Acuity; IOP = Intraocular Pressure; CCT = Central Corneal Thickness; ACD = Anterior Chamber Depth; SER = Spherical Equivalent Error