Skip to main content
. 2005 Jun;43(6):2668–2673. doi: 10.1128/JCM.43.6.2668-2673.2005

TABLE 6.

Sensitivity of the multiplex real-time PCR assay for detection of E. coli O157:H7 strain Tw04 in raw milk and apple juice after enrichment

No. of CFU/ml Sensitivity for detection ina:
Milk
Apple juice
0 h 2 h 3 h 4 h 5 h 10 h 0 h 2 h 3 h 4 h 5 h 10 h
103 + + + + + + + + + +
102 + + + + + + + +
101 + + + + + +
100 + + + +
0
a

The plus or minus sign indicates whether or not the relative fluorescent intensity after 40 cycles was greater than the threshold value for the negative control.