TABLE 4.
Recovery of C. difficile from high-reach environmental sites on wards A and B at 6-month intervals throughout the study
| Ward and location | Culture positivity on the following sample date (mo/yr)a:
|
|||||||
|---|---|---|---|---|---|---|---|---|
| 08/97 | 06/98 | 05/99 | 11/99 | 06/00 | 11/00 | 05/01 | 10/01 | |
| Ward A | ||||||||
| Bay curtain rails | + | + | + | + | ||||
| Bay overbed lamps | + | + | + | + | + | |||
| Bay partitions | + | + | + | + | ||||
| Bay window frames | + | + | ||||||
| Door tops | + | + | + | + | ||||
| Door frames | + | + | ||||||
| Fire hoses | + | + | + | + | ||||
| Ward smoke detector | ||||||||
| Toilet curtain rails | + | + | ||||||
| Treatment room supplies caddy | ||||||||
| Ward B | ||||||||
| Bay curtain rails | + | + | + | |||||
| Bay overbed lamps | + | + | + | + | + | |||
| Bay partitions | + | + | + | + | ||||
| Bay window frames | + | + | ||||||
| Door tops | + | + | ||||||
| Door frames | + | + | ||||||
| Fire hoses | + | + | ||||||
| Ward smoke detector | ||||||||
| Toilet curtain rails | + | + | ||||||
| Treatment room supplies caddy | ||||||||
+, at least one of the samples from site type was culture positive for C. difficile.