. 2024 Feb 12;67(7):1505–1516. doi: 10.1007/s10840-024-01761-7

Table 2.

Individual procedural and follow-up data

Case PLSVC type Targeted CS-branch CS-lead Implanted device Procedure duration [min] Fluoroscopy time [min] LV sensing [mV] LV treshold [V] LVEF before [%] LVEF after [%] QRS before [ms] QRS after [ms]
# 1 III B Posterolateral Quadripolar passive fixation CRT-P 200 46 4.6 2 22 22 145 130
# 2 III A Lateral Quadripolar passive fixation CRT-D 180 30 16 0.75 49 54 150 125
# 3 III B Posterolateral Quadripolar active fixation CRT-D 167 46 20 0.8 30 48 155 98
# 4 III A Posterolateral Bipolar passive fixation CRT-D 102 11 Paced 1.7 30 38 150 130
# 5 III A Posterolateral Quadripolar active fixation CRT-P 104 14 20 1.1 52 52 150 145

Number of patients n = 5; only including patients who received a resynchronization system. LV threshold was measured with a pulse duration of 0.5 ms.