Skip to main content
. 2024 Oct 30;24:1321. doi: 10.1186/s12903-024-05105-9

Table 3.

The angle errors in various dimensions between the AR group and FH group

AR Group FH Group P Value Accuracy promotion
Three-Dimensional Space (°) 1.94 (1.30, 2.93) 5.06 (3.61, 9.22) < 0.0001**** 61.6%
Coronal Plane, xy (°) 2.22 (0.73, 3.79) 1.89 (0.64, 7.12) 0.784 -
Horizontal Plane, xz (°) 1.48 (0.69, 3.76) 4.51 (2.04, 9.44) 0.0095** 67.2%
Sagittal Plane, yz (°) 1.24 (0.44, 2.72) 3.87 (2.37, 9.17) 0.0005*** 68.0%

Note: Data are represented by the median (P25, P75).

Abbreviation: AR: Augmented Reality; FH: Free Hand