Table 1.

Acquisition protocols.

Study cohort Scanner Field strength Resolution voxel size (mm) b-values (s/mm2) Gradient directions TR/TE (ms) No. of scanners
LREN Siemens Prisma 3T 96 × 106
2 × 2 × 2
1000 30 71/4100 1
UMon Siemens Prisma 3T 150 × 154
1.7 × 1.7 × 1.7
1000 30 71/4100 1
CHUV Siemens Prisma 3T 150 × 154
1.7 × 1.7 × 1.7
1000 30 71/4100 1
SVIP Siemens Trio Tim 3T 128 × 128
2 × 2 × 2
1000 30 80/10000 2
UKBB Siemens Skyra 3T 104 × 104
2.01 × 2.01 × 1
1000 53 92/3600 2
HCP Siemens Prisma 3T 168 × 144
1.25 × 1.25 × 1.25
1000 111 89.5/5520 1

LREN: Laboratoire de Recherche en Neuroimagerie; UMon: Université de Montréal; CHUV: Centre Hospitalier Universitaire Vaudois; SVIP: Simons Variation in Individuals Project; UKBB: United Kingdom BioBank; HCP: Human Connectome Project - Young Adult.