Skip to main content
. 2024 Oct 28;12:e18221. doi: 10.7717/peerj.18221

Table 2. Mean, standard deviation and 95% confidence interval of fatigue failure load (FFL) (N) and cycles for failure (CFF) in each experimental group.

Groups FFL (N) CFF
Mean ± standard deviation 95% CI Mean ± standard deviation 95% CI
BC-B 427.0 ± 139.5B [338.4–515.7] 100,450 ± 57,389 B [63,986–136,914]
BC-GP 414.5 ± 139.9B [325.6–503.5] 93,795 ± 56,471B [57,915–129,675]
AP-B 370.8 ± 87.1B [315.4–425.2] 77,972 ± 35,910B [55,156–100,789]
AP-GP 525.0 ± 231.1A,B [378.1–671.8] 140,666 ± 94,350A,B [80,718–200,613]
C+ 450.0 ± 81.1B [398.4–501.5] 109,953 ± 31,446B [89,972–129,933]
C− 687.5 ± 206.5A [556.2–818.7] 203,177 ± 83,114A [150,369–255,986]

Note:

Different uppercase letters in the columns mean statistically significant difference (Kaplan-Meier and Mantel-Cox post-hoc tests) for FFL and CFF (p < 0.05).